Here's the solution that might possibly help solve Nokia X6 mouthpiece microphone failure, a problem that no audio sounds can be heard from the other receiving device during a call is created.
Nokia X6 Microphone sound failure solution
The
red lines indicated in the solution above is the microphone's supply
voltage if this voltage is cut or not present the mic will not tend to
work. There are also resistors that where the digital audio signal is
flow across to this components that has a resistance value of 100ohms
each, check and replace it first before attempting to replace the
Digital Microphone Module.